Detailed Product Description
B6V8 balance charger with cooling fans Max. charge power 50W, voltage range: DC11.0~18.0 V 1-6s lithium battery appealing
B6 V8 Lipo balance charger (Model: FFL-B6 V8), Newest! Circuit power: Max. charge power 50W, voltage range: DC 11.0~18.0 Voltage
Specification Operating voltage DC 11~18 volts Idling current approx. 100mA Charge/discharge power max. 50/5W NiCd/MH 1~15 cells LiIo/LiPo/LiFe 1~6 series Pb 2~20V Charge current 0.1 to 5.0A Discharg current 0.1 to 1.0A No. of cycle 1 to 5 times Battery data memory up to 5 data Weight 260g Dimension 117x85.5x30 mm
User's setting-up parameters Lithium battery voltage type LiIo:3.6V, LiPo:3.7V, LiFe:3.3V NiCd Delta-peak voltage sensitivity 5 to 20mV NiMH Delta-peak voltage sensitivity 5 to 20mV Battery temperature cut-off 20 to 80C or OFF Waste time between charge/discharge 1 to 60 min. Trickle charge mode ON/OFF, up to 200mA Integral timer limit for safety 10 to 720 min.or OFF Maximum charging capacity limit for safety 10 to 9990mAh or OFF Key beep and buzzer sound ON/OFF Input power low alert 10 to 11V
Welcome you orders!
→Operating software Every operating program in the unit is controlled with mutual links and communications to prevent every possible error, so it introduces the maximum safety, such as input voltage warning, reverse polarity protection and Lithium cell-count input error warning.
→Individual voltage balancer for Lithium batteries B6 V8 has an individual cell voltage balancer inside. So it does not need any balancer separately when charging Lithium batteries (LiIo/LiPo/LiFe) for voltage balancing.
→Accept various types of Lithium battery B6 V8 can accept three types of Lithium batteries - LiIo, LiPo and LiFe. They have different characteristics by their chemistry. You can select any one of them that you are going to process before the job. For their specifications, refer 'Warnings and safety notes' section. →Lithium battery 'Fast' and 'Storage' mode You can charge Lithium battery for special purposes. 'Fast' charge reduces the charging time of Lithium battery and 'Storage' mode controls the final voltage of the battery to be suit for long time storage.
→Maximum safety Delta-peak sensitivity : The automatic charge termination program works on the principle of the Delta-peak voltage detection. (NiCd/NiMH) Auto-charge current limit : When charging NiCd or NiMH at 'AUTO' current mode, you can set the upper limit of charge current to avoid from feeding high current to the battery. This is very useful when charging the low impedance and small capacity NiMH battery in 'AUTO' mode. Capacity limit : The charging capacity always calculated by multiple of the charging current and time. If the charging capacity exceeds the limit the process will be terminated automatically when you set the maximum value.
→Data store/load For users convenience it can store maximum 10 data of different batteries. You can establish the data contains program setting of the battery to charge or discharge continually. These data can be called out at any time you need and the process can be executed without program setting.
→Cyclic charging/discharging Perform 1 to 5 cycles of charge>discharge or discharge>charge continually for battery refreshing and balancing.
→PC based analysis using USB communication For technical expert, B6 V8 offers PC based program can analysis the characteristic of the battery by USB port. It shows a graph of voltage, current, capacity and temperature curves. It also shows the individual voltage of each cell in the Lithium battery pack.
→Robust outer aluminum case High-quality aluminum case is durable and very efficient to cool out the internal heat.
|